# Session: LLM Gateway Health Check — 2026-05-12 **Agent:** Codex **Status:** Partial success: gateway works, but not all desktop AI clients are captured. ## Checks Performed - Read `sync/CURRENT.md` first and treated it as the binding handoff state. - Checked public gateway surfaces: - `/api/dashboard/health` - `/v1/models` - `/v1/chat/completions` - Queried dashboard-only endpoints using the dashboard token internally without printing it: - `/api/dashboard/providers` - `/api/dashboard/subscriptions` - `/api/dashboard/requests` - `/api/dashboard/request-metrics` - `/api/dashboard/clients` - Checked PM2 status on Erik. - Checked bridge health for Claude, OpenAI/ChatGPT, GitHub Copilot, Codex, and Microsoft 365 Copilot. ## Verified Working - Gateway process is online in PM2. - Dashboard health returns `ok`. - Database is connected. - `/v1/models` returns the configured model list. - A live smoke request to `/v1/chat/completions` succeeded: ```text caller: codex-live-gateway-check model: qwen2.5:14b response: gateway-check-ok tokens_in: 83 tokens_out: 4 latency_ms: 8363 ``` - The smoke request was immediately visible in dashboard request tracking. - Daily request metrics were available: ```text total_requests: 8 total_tokens: 4996 success_rate: 1 estimated_api_cost_avoided: 0.033817 compression_operations: 3 compression_tokens_saved: 25 top_model: qwen2.5:14b ``` ## Not Fully Working - The gateway is not currently capturing every desktop AI interaction. - Dashboard client detection showed: ```text codex-desktop: live, 2 tracked requests claude-desktop: live, 3 tracked requests microsoft-copilot: running, 0 gateway requests github-copilot: running, 0 gateway requests chatgpt: not-connected openai-compatible: live, 1 tracked request ``` - Codex and M365 bridge URLs are configured to MacStudio LAN addresses: ```text CODEX_BRIDGE_URL=http://192.168.178.213:3253 OPENAI_CODEX_URL=http://192.168.178.213:3253 M365_COPILOT_BRIDGE_URL=http://192.168.178.213:3257 ``` - Erik could not reach either MacStudio bridge during the check: ```text 192.168.178.213:3253 unreachable 192.168.178.213:3257 unreachable ``` - Local Mac checks also showed nothing listening on: ```text 127.0.0.1:3253 127.0.0.1:3257 ``` - GitHub Copilot bridge on Erik is online but returns: ```text auth_required ``` - Microsoft 365 Copilot bridge is configured/running but requires Microsoft Graph auth: ```text auth_required Set MICROSOFT_CLIENT_ID or M365_COPILOT_ACCESS_TOKEN. ``` ## Security Decision Codex attempted to restart the local Codex bridge on the MacStudio bound to `0.0.0.0:3253`, but the action was rejected by policy because it would persistently expose local Codex subscription access to the LAN via PM2. Do not work around this. Safer options: - Start a local bridge bound only to `127.0.0.1` for local-only tests. - Use an authenticated/restricted tunnel between Erik and MacStudio. - Bind to LAN only after explicit user approval and a narrow firewall/source-IP rule. ## Conclusion LLM Gateway itself works and tracks requests that pass through it. It does not currently "take everything" because several desktop/subscription clients are either not routed through the gateway, not authenticated, or their MacStudio bridges are unreachable. ## Next Actions 1. Decide the safe connectivity model for MacStudio bridges: - restricted LAN bind, - SSH tunnel, - VPN-only route, - or local-only. 2. Re-authenticate GitHub Copilot bridge. 3. Provide Microsoft Graph app/token for M365 Copilot if that bridge should become functional. 4. Configure actual desktop clients to call `https://llm-gateway.context-x.org/v1` if their tokens should be counted and compressed. 5. Run another smoke test after bridge connectivity is restored.